SENEC
SENEC.Home V3 hybrid 2.5
Residential AIO
All-in-one residential storage system for installation and compliance comparison.
AC Phase
3P
AC Rated Power
4.6 kW
MPPT Count
2
Battery Capacity Min
2.5 kWh
Backup / EPS Supported
true
IP Rating
IP20
Pays applicables
Prompt AI installateur
Générez des modèles de prompt prêts pour installateurs sur ChatGPT ou Gemini.
Core Electrical
Source de données
AC Phase
Version source: 1.9
AC Rated Power
Version source: 1.9
Max AC Output Current
Version source: 1.9
Power Factor Range
Version source: 1.9
THD
Version source: 1.9
MPPT Count
Version source: 1.9
Max DC Voltage
Version source: 1.9
MPPT Voltage Range
Version source: 1.9
Max Current per MPPT
Version source: 1.9
Recommended PV Power
Version source: 1.9
Max Efficiency
Version source: 1.9
EU Efficiency
Version source: 1.9
| AC Phase | 3P |
| AC Rated Power | 4.6 kW |
| Max AC Output Current | 20 A |
| Power Factor Range | 0.8 leading to 0.8 lagging |
| THD | - |
| MPPT Count | 2 |
| Max DC Voltage | 750 V |
| MPPT Voltage Range | 75-650 V |
| Max Current per MPPT | 20 A |
| Recommended PV Power | 7.1 kWp |
| Max Efficiency | 97.4 % |
| EU Efficiency | 96.5 % |
Battery
Source de données
Battery Chemistry
Version source: 1.9
Battery Voltage Class
Version source: 1.9
Battery Capacity Min
Version source: 1.9
Battery Capacity Max
Version source: 1.9
Max Charge Power
Version source: 1.9
Max Discharge Power
Version source: 1.9
Round-trip Efficiency
Version source: 1.9
| Battery Chemistry | LFP |
| Battery Voltage Class | LV |
| Battery Capacity Min | 2.5 kWh |
| Battery Capacity Max | 2.5 kWh |
| Max Charge Power | 0.62 kW |
| Max Discharge Power | 4.6 kW |
| Round-trip Efficiency | 92 % |
Backup
Source de données
Backup / EPS Supported
Version source: 1.9
Backup Rated Power
Version source: 1.9
Switch Time
Version source: 1.9
Black Start
Version source: 1.9
Parallel Support
Version source: 1.9
Max Parallel Units
Version source: 1.9
Generator Input Supported
Version source: 1.9
| Backup / EPS Supported | true |
| Backup Rated Power | 1.5 kW |
| Switch Time | 15000 ms |
| Black Start | Yes |
| Parallel Support | No |
| Max Parallel Units | - |
| Generator Input Supported | false |
EMS & Communication
Source de données
EMS Modes
Version source: 1.9
Export Limitation Supported
Version source: 1.9
Meter Type Supported
Version source: 1.9
Remote Monitoring Platform
Version source: 1.9
API Supported
Version source: 1.9
| EMS Modes | Self-consumption, Time-of-Use |
| Export Limitation Supported | true |
| Meter Type Supported | SENEC Power Meter (included) |
| Remote Monitoring Platform | SENEC.App / my.senec.com |
| API Supported | true |
Environment & Mechanical
Source de données
Cooling Method
Version source: 1.9
IP Rating
Version source: 1.9
Operating Temp Range
Version source: 1.9
Max Altitude
Version source: 1.9
Humidity Range
Version source: 1.9
Wiring Terminal Type
Version source: 1.9
Max Cable Size
Version source: 1.9
Dimensions (W x H x D)
Version source: 1.9
Weight
Version source: 1.9
Noise
Version source: 1.9
| Cooling Method | Fan |
| IP Rating | IP20 |
| Operating Temp Range | 5-40 |
| Max Altitude | 2000 m |
| Humidity Range | 10-85% |
| Wiring Terminal Type | MC4 / Spring terminal |
| Max Cable Size | 6 mm2 |
| Dimensions (W x H x D) | 1135*535*535 mm |
| Weight | 83 kg |
| Noise | 40 dB(A) |
Compliance & Warranty
Source de données
DC Surge Protection
Version source: 1.9
AC Surge Protection
Version source: 1.9
AFCI
Version source: 1.9
Anti-islanding
Version source: 1.9
Certifications
Version source: 1.9
| DC Surge Protection | Type 2 |
| AC Surge Protection | Type 2 |
| AFCI | Yes |
| Anti-islanding | Yes |
| Certifications | VDE-AR-N 4105:2018, CE, UN 38.3 |
Conformité de raccordement réseau par pays
| Pays | Statut | Code réseau | Preuve | Notes |
|---|---|---|---|---|
| DE | Approuvé | VDE-AR-N 4105:2018 | Ouvrir le fichier | Full compliance with German grid regulations. |