SENEC
SENEC.Home V3 hybrid 2.5
Residential AIO
All-in-one residential storage system for installation and compliance comparison.
AC Phase
3P
AC Rated Power
4.6 kW
MPPT Count
2
Battery Capacity Min
2.5 kWh
Backup / EPS Supported
true
IP Rating
IP20
Applicable Countries
Installer AI Prompt
Generate installer-ready prompt templates for ChatGPT or Gemini.
Core Electrical
Data source
AC Phase
Source Version: 1.9
AC Rated Power
Source Version: 1.9
Max AC Output Current
Source Version: 1.9
Power Factor Range
Source Version: 1.9
THD
Source Version: 1.9
MPPT Count
Source Version: 1.9
Max DC Voltage
Source Version: 1.9
MPPT Voltage Range
Source Version: 1.9
Max Current per MPPT
Source Version: 1.9
Recommended PV Power
Source Version: 1.9
Max Efficiency
Source Version: 1.9
EU Efficiency
Source Version: 1.9
| AC Phase | 3P |
| AC Rated Power | 4.6 kW |
| Max AC Output Current | 20 A |
| Power Factor Range | 0.8 leading to 0.8 lagging |
| THD | - |
| MPPT Count | 2 |
| Max DC Voltage | 750 V |
| MPPT Voltage Range | 75-650 V |
| Max Current per MPPT | 20 A |
| Recommended PV Power | 7.1 kWp |
| Max Efficiency | 97.4 % |
| EU Efficiency | 96.5 % |
Battery
Data source
Battery Chemistry
Source Version: 1.9
Battery Voltage Class
Source Version: 1.9
Battery Capacity Min
Source Version: 1.9
Battery Capacity Max
Source Version: 1.9
Max Charge Power
Source Version: 1.9
Max Discharge Power
Source Version: 1.9
Round-trip Efficiency
Source Version: 1.9
| Battery Chemistry | LFP |
| Battery Voltage Class | LV |
| Battery Capacity Min | 2.5 kWh |
| Battery Capacity Max | 2.5 kWh |
| Max Charge Power | 0.62 kW |
| Max Discharge Power | 4.6 kW |
| Round-trip Efficiency | 92 % |
Backup
Data source
Backup / EPS Supported
Source Version: 1.9
Backup Rated Power
Source Version: 1.9
Switch Time
Source Version: 1.9
Black Start
Source Version: 1.9
Parallel Support
Source Version: 1.9
Max Parallel Units
Source Version: 1.9
Generator Input Supported
Source Version: 1.9
| Backup / EPS Supported | true |
| Backup Rated Power | 1.5 kW |
| Switch Time | 15000 ms |
| Black Start | Yes |
| Parallel Support | No |
| Max Parallel Units | - |
| Generator Input Supported | false |
EMS & Communication
Data source
EMS Modes
Source Version: 1.9
Export Limitation Supported
Source Version: 1.9
Meter Type Supported
Source Version: 1.9
Remote Monitoring Platform
Source Version: 1.9
API Supported
Source Version: 1.9
| EMS Modes | Self-consumption, Time-of-Use |
| Export Limitation Supported | true |
| Meter Type Supported | SENEC Power Meter (included) |
| Remote Monitoring Platform | SENEC.App / my.senec.com |
| API Supported | true |
Environment & Mechanical
Data source
Cooling Method
Source Version: 1.9
IP Rating
Source Version: 1.9
Operating Temp Range
Source Version: 1.9
Max Altitude
Source Version: 1.9
Humidity Range
Source Version: 1.9
Wiring Terminal Type
Source Version: 1.9
Max Cable Size
Source Version: 1.9
Dimensions (W x H x D)
Source Version: 1.9
Weight
Source Version: 1.9
Noise
Source Version: 1.9
| Cooling Method | Fan |
| IP Rating | IP20 |
| Operating Temp Range | 5-40 |
| Max Altitude | 2000 m |
| Humidity Range | 10-85% |
| Wiring Terminal Type | MC4 / Spring terminal |
| Max Cable Size | 6 mm2 |
| Dimensions (W x H x D) | 1135*535*535 mm |
| Weight | 83 kg |
| Noise | 40 dB(A) |
Compliance & Warranty
Data source
DC Surge Protection
Source Version: 1.9
AC Surge Protection
Source Version: 1.9
AFCI
Source Version: 1.9
Anti-islanding
Source Version: 1.9
Certifications
Source Version: 1.9
| DC Surge Protection | Type 2 |
| AC Surge Protection | Type 2 |
| AFCI | Yes |
| Anti-islanding | Yes |
| Certifications | VDE-AR-N 4105:2018, CE, UN 38.3 |
Grid Connection Compliance by Country
| Country | Status | Grid Code | Evidence | Notes |
|---|---|---|---|---|
| DE | Approved | VDE-AR-N 4105:2018 | Open file | Full compliance with German grid regulations. |