Sungrow
SH5.0RT
Residential Hybrid Inverter
Residential hybrid inverter with battery and backup interface.
AC Phase
3P
AC Rated Power
5 kW
MPPT Count
2
Battery Voltage Class
HV
Backup / EPS Supported
true
IP Rating
IP65
Pays applicables
Prompt AI installateur
Générez des modèles de prompt prêts pour installateurs sur ChatGPT ou Gemini.
Core Electrical
Source de données
AC Phase
URL source: https://ger.sungrowpower.com/upload/file/20220824/DE%20DS%20SH5.0RT%206.0RT%208.0RT%2010RT%20Datenblatt.pdf
Version source: V1.21
AC Rated Power
URL source: https://ger.sungrowpower.com/upload/file/20220824/DE%20DS%20SH5.0RT%206.0RT%208.0RT%2010RT%20Datenblatt.pdf
Version source: V1.21
Max AC Output Current
URL source: https://ger.sungrowpower.com/upload/file/20220824/DE%20DS%20SH5.0RT%206.0RT%208.0RT%2010RT%20Datenblatt.pdf
Version source: V1.21
Power Factor Range
URL source: https://ger.sungrowpower.com/upload/file/20220824/DE%20DS%20SH5.0RT%206.0RT%208.0RT%2010RT%20Datenblatt.pdf
Version source: V1.21
THD
URL source: https://ger.sungrowpower.com/upload/file/20220824/DE%20DS%20SH5.0RT%206.0RT%208.0RT%2010RT%20Datenblatt.pdf
Version source: V1.21
MPPT Count
URL source: https://ger.sungrowpower.com/upload/file/20220824/DE%20DS%20SH5.0RT%206.0RT%208.0RT%2010RT%20Datenblatt.pdf
Version source: V1.21
Max DC Voltage
URL source: https://ger.sungrowpower.com/upload/file/20220824/DE%20DS%20SH5.0RT%206.0RT%208.0RT%2010RT%20Datenblatt.pdf
Version source: V1.21
MPPT Voltage Range
URL source: https://ger.sungrowpower.com/upload/file/20220824/DE%20DS%20SH5.0RT%206.0RT%208.0RT%2010RT%20Datenblatt.pdf
Version source: V1.21
Max Current per MPPT
URL source: https://ger.sungrowpower.com/upload/file/20220824/DE%20DS%20SH5.0RT%206.0RT%208.0RT%2010RT%20Datenblatt.pdf
Version source: V1.21
Max Efficiency
URL source: https://ger.sungrowpower.com/upload/file/20220824/DE%20DS%20SH5.0RT%206.0RT%208.0RT%2010RT%20Datenblatt.pdf
Version source: V1.21
EU Efficiency
URL source: https://ger.sungrowpower.com/upload/file/20220824/DE%20DS%20SH5.0RT%206.0RT%208.0RT%2010RT%20Datenblatt.pdf
Version source: V1.21
| AC Phase | 3P |
| AC Rated Power | 5 kW |
| Max AC Output Current | 7.6 A |
| Power Factor Range | 0.8 leading to 0.8 lagging |
| THD | - |
| MPPT Count | 2 |
| Max DC Voltage | 1000 V |
| MPPT Voltage Range | 150-950 V |
| Max Current per MPPT | 12.5 A |
| Max Efficiency | 98.4 % |
| EU Efficiency | 97.9 % |
Battery
Source de données
Battery Voltage Class
URL source: https://ger.sungrowpower.com/upload/file/20220824/DE%20DS%20SH5.0RT%206.0RT%208.0RT%2010RT%20Datenblatt.pdf
Version source: V1.21
Battery DC Voltage Range
URL source: https://ger.sungrowpower.com/upload/file/20220824/DE%20DS%20SH5.0RT%206.0RT%208.0RT%2010RT%20Datenblatt.pdf
Version source: V1.21
Max Charge Power
URL source: https://ger.sungrowpower.com/upload/file/20220824/DE%20DS%20SH5.0RT%206.0RT%208.0RT%2010RT%20Datenblatt.pdf
Version source: V1.21
Max Discharge Power
URL source: https://ger.sungrowpower.com/upload/file/20220824/DE%20DS%20SH5.0RT%206.0RT%208.0RT%2010RT%20Datenblatt.pdf
Version source: V1.21
| Battery Voltage Class | HV |
| Battery DC Voltage Range | 150-600 V |
| Max Charge Power | 5 kW |
| Max Discharge Power | 5 kW |
Backup
Source de données
Backup / EPS Supported
URL source: https://ger.sungrowpower.com/upload/file/20220824/DE%20DS%20SH5.0RT%206.0RT%208.0RT%2010RT%20Datenblatt.pdf
Version source: V1.21
Backup Rated Power
URL source: https://ger.sungrowpower.com/upload/file/20220824/DE%20DS%20SH5.0RT%206.0RT%208.0RT%2010RT%20Datenblatt.pdf
Version source: V1.21
Switch Time
URL source: https://ger.sungrowpower.com/upload/file/20220824/DE%20DS%20SH5.0RT%206.0RT%208.0RT%2010RT%20Datenblatt.pdf
Version source: V1.21
Black Start
URL source: https://ger.sungrowpower.com/upload/file/20220824/DE%20DS%20SH5.0RT%206.0RT%208.0RT%2010RT%20Datenblatt.pdf
Version source: V1.21
Parallel Support
URL source: https://ger.sungrowpower.com/upload/file/20220824/DE%20DS%20SH5.0RT%206.0RT%208.0RT%2010RT%20Datenblatt.pdf
Version source: V1.21
Max Parallel Units
URL source: https://ger.sungrowpower.com/upload/file/20220824/DE%20DS%20SH5.0RT%206.0RT%208.0RT%2010RT%20Datenblatt.pdf
Version source: V1.21
Generator Input Supported
URL source: https://ger.sungrowpower.com/upload/file/20220824/DE%20DS%20SH5.0RT%206.0RT%208.0RT%2010RT%20Datenblatt.pdf
Version source: V1.21
| Backup / EPS Supported | true |
| Backup Rated Power | 5 kW |
| Switch Time | 20 ms |
| Black Start | Yes |
| Parallel Support | Yes |
| Max Parallel Units | 5 units |
| Generator Input Supported | false |
EMS & Communication
Source de données
EMS Modes
URL source: https://ger.sungrowpower.com/upload/file/20220824/DE%20DS%20SH5.0RT%206.0RT%208.0RT%2010RT%20Datenblatt.pdf
Version source: V1.21
Export Limitation Supported
URL source: https://ger.sungrowpower.com/upload/file/20220824/DE%20DS%20SH5.0RT%206.0RT%208.0RT%2010RT%20Datenblatt.pdf
Version source: V1.21
Meter Type Supported
URL source: https://ger.sungrowpower.com/upload/file/20220824/DE%20DS%20SH5.0RT%206.0RT%208.0RT%2010RT%20Datenblatt.pdf
Version source: V1.21
Remote Monitoring Platform
URL source: https://ger.sungrowpower.com/upload/file/20220824/DE%20DS%20SH5.0RT%206.0RT%208.0RT%2010RT%20Datenblatt.pdf
Version source: V1.21
| EMS Modes | Self-consumption, Time-of-use, Off-grid |
| Export Limitation Supported | true |
| Meter Type Supported | Sungrow S100 Smart Meter |
| Remote Monitoring Platform | iSolarCloud |
Environment & Mechanical
Source de données
Cooling Method
URL source: https://ger.sungrowpower.com/upload/file/20220824/DE%20DS%20SH5.0RT%206.0RT%208.0RT%2010RT%20Datenblatt.pdf
Version source: V1.21
Max Altitude
URL source: https://ger.sungrowpower.com/upload/file/20220824/DE%20DS%20SH5.0RT%206.0RT%208.0RT%2010RT%20Datenblatt.pdf
Version source: V1.21
IP Rating
URL source: https://ger.sungrowpower.com/upload/file/20220824/DE%20DS%20SH5.0RT%206.0RT%208.0RT%2010RT%20Datenblatt.pdf
Version source: V1.21
Operating Temp Range
URL source: https://ger.sungrowpower.com/upload/file/20220824/DE%20DS%20SH5.0RT%206.0RT%208.0RT%2010RT%20Datenblatt.pdf
Version source: V1.21
Dimensions (W x H x D)
URL source: https://ger.sungrowpower.com/upload/file/20220824/DE%20DS%20SH5.0RT%206.0RT%208.0RT%2010RT%20Datenblatt.pdf
Version source: V1.21
Weight
URL source: https://ger.sungrowpower.com/upload/file/20220824/DE%20DS%20SH5.0RT%206.0RT%208.0RT%2010RT%20Datenblatt.pdf
Version source: V1.21
Interfaces
URL source: https://ger.sungrowpower.com/upload/file/20220824/DE%20DS%20SH5.0RT%206.0RT%208.0RT%2010RT%20Datenblatt.pdf
Version source: V1.21
| Cooling Method | Natural |
| Max Altitude | 4000 m |
| IP Rating | IP65 |
| Operating Temp Range | -25 to 60 |
| Dimensions (W x H x D) | 460*540*170 mm |
| Weight | 27 kg |
| Interfaces | - |
Compliance & Warranty
Source de données
DC Surge Protection
URL source: https://ger.sungrowpower.com/upload/file/20220824/DE%20DS%20SH5.0RT%206.0RT%208.0RT%2010RT%20Datenblatt.pdf
Version source: V1.21
AC Surge Protection
URL source: https://ger.sungrowpower.com/upload/file/20220824/DE%20DS%20SH5.0RT%206.0RT%208.0RT%2010RT%20Datenblatt.pdf
Version source: V1.21
AFCI
URL source: https://ger.sungrowpower.com/upload/file/20220824/DE%20DS%20SH5.0RT%206.0RT%208.0RT%2010RT%20Datenblatt.pdf
Version source: V1.21
Anti-islanding
URL source: https://ger.sungrowpower.com/upload/file/20220824/DE%20DS%20SH5.0RT%206.0RT%208.0RT%2010RT%20Datenblatt.pdf
Version source: V1.21
Certifications
URL source: https://ger.sungrowpower.com/upload/file/20220824/DE%20DS%20SH5.0RT%206.0RT%208.0RT%2010RT%20Datenblatt.pdf
Version source: V1.21
| DC Surge Protection | Type II |
| AC Surge Protection | Type II |
| AFCI | Yes |
| Anti-islanding | Yes |
| Certifications | VDE-AR-N 4105, EN 50549-1, CE, IEC 62109 |
Conformité de raccordement réseau par pays
| Pays | Statut | Code réseau | Preuve | Notes |
|---|---|---|---|---|
| DE | Approuvé | VDE-AR-N 4105 | Ouvrir le fichier | Fully compliant with German grid regulations. |