Energidea

Panoramica della serie prodotti

Fronius Fronius Primo GEN24 Plus

9 Sotto-modelli

Fronius Fronius Primo GEN24 Plus

Selling Points

  • Active cooling for longer life.
  • PV Point standard backup.
  • Open interfaces for smart home.

Paesi applicabili

AustriaBelgiumSwitzerlandGermanySpainFranceItalyNetherlands

Sotto-modelli

9

Prompt AI per installatori

Genera template di prompt pronti per installatori su ChatGPT o Gemini.

Technical Data

Campo

Fronius Primo GEN24 3.0 Plus

Vedi modello

Fronius Primo GEN24 3.6 Plus

Vedi modello

Fronius Primo GEN24 4.0 Plus

Vedi modello

Fronius Primo GEN24 4.6 Plus

Vedi modello

Fronius Primo GEN24 5.0 Plus

Vedi modello

Fronius Primo GEN24 6.0 Plus

Vedi modello

Fronius Primo-GEN24-3.0-Plus

Vedi modello

Fronius Primo-GEN24-4.6-Plus

Vedi modello

Fronius Primo-GEN24-6.0-Plus

Vedi modello
Core Electrical
AC Phase3P1P1P1P1P1P1P1P1P
AC Rated Power3 kW3.68 kW4 kW4.6 kW5 kW6 kW3 kW4.6 kW6 kW
Max AC Output Current19.4 A23.7 A25.8 A27.5 A27.5 A27.5 A13 A20 A26.1 A
Power Factor Range0.8 - 1 ind./cap.0.8 - 1 ind./cap.0.8 - 1 ind./cap.0.8 - 1 ind./cap.0.8 - 1 ind./cap.0.8 - 1 ind./cap.0.7 - 1 ind./cap.0.7 - 1 ind./cap.0.7 - 1 ind./cap.
THD------3 %3 %3 %
MPPT Count222222222
Max DC Voltage600 V600 V600 V600 V600 V600 V600 V600 V600 V
MPPT Voltage Range65 - 530 V65 - 530 V65 - 530 V65 - 530 V65 - 530 V65 - 530 V65 - 530 V65 - 530 V65 - 530 V
Max Current per MPPT22 A22 A22 A22 A22 A22 A---
Max Efficiency97.6 %97.6 %97.6 %97.6 %97.6 %97.6 %97.6 %97.6 %97.6 %
EU Efficiency97.2 %97.2 %97.2 %97.2 %97.2 %97.2 %---
Battery
Battery Voltage ClassHVHVHVHVHVHVHVHVHV
Battery DC Voltage Range150 - 455 V150 - 455 V150 - 455 V150 - 455 V150 - 455 V150 - 455 V150 - 455 V150 - 455 V150 - 455 V
Max Charge Power3 kW3.68 kW4 kW4.6 kW5 kW6 kW3 kW4.6 kW6 kW
Max Discharge Power3 kW3.68 kW4 kW4.6 kW5 kW6 kW3 kW4.6 kW6 kW
Backup
Backup / EPS Supportedtruetruetruetruetruetruetruetruetrue
Backup Rated Power3 kW3.68 kW4 kW4.6 kW5 kW6 kW3 kW4.6 kW6 kW
Switch Time90000 ms90000 ms90000 ms90000 ms90000 ms90000 ms---
Black StartYesYesYesYesYesYesYesYesYes
Parallel SupportYesYesYesYesYesYesYesYesYes
Max Parallel Units3 units3 units3 units3 units3 units3 units3 units3 units3 units
Generator Input Supported------falsefalsefalse
EMS & Communication
EMS ModesSelf-consumption, Multi-flow, PV PointSelf-consumption, Multi-flow, PV PointSelf-consumption, Multi-flow, PV PointSelf-consumption, Multi-flow, PV PointSelf-consumption, Multi-flow, PV PointSelf-consumption, Multi-flow, PV PointSelf-consumption optimizationSelf-consumption optimizationSelf-consumption optimization
Export Limitation Supportedtruetruetruetruetruetruetruetruetrue
Meter Type Supported------Fronius Smart MeterFronius Smart MeterFronius Smart Meter
Remote Monitoring PlatformSolar.webSolar.webSolar.webSolar.webSolar.webSolar.webFronius Solar.webFronius Solar.webFronius Solar.web
Environment & Mechanical
Cooling MethodFanFanFanFanFanFanFanFanFan
Max Altitude4000 m4000 m4000 m4000 m4000 m4000 m3000 m3000 m3000 m
IP RatingIP66IP66IP66IP66IP66IP66IP66IP66IP66
Operating Temp Range-40 to +60-40 to +60-40 to +60-40 to +60-40 to +60-40 to +60-25 - 60-25 - 60-25 - 60
Dimensions (W x H x D)530 * 474 * 165 mm530 * 474 * 165 mm530 * 474 * 165 mm530 * 474 * 165 mm530 * 474 * 165 mm530 * 474 * 165 mm528 x 474 x 164 mm528 x 474 x 164 mm528 x 474 x 164 mm
Weight15.4 kg15.4 kg15.4 kg15.4 kg15.4 kg15.4 kg15.4 kg15.4 kg15.4 kg
Interfaces------Modbus RTU, Modbus TCP, WLAN, EthernetModbus RTU, Modbus TCP, WLAN, EthernetModbus RTU, Modbus TCP, WLAN, Ethernet
Compliance & Warranty
DC Surge ProtectionType 1 + 2Type 1 + 2Type 1 + 2Type 1 + 2Type 1 + 2Type 1 + 2---
AC Surge ProtectionType 3Type 3Type 3Type 3Type 3Type 3---
AFCIYesYesYesYesYesYes---
Anti-islandingYesYesYesYesYesYesYesYesYes
CertificationsVDE-AR-N 4105, EN 50549-1, CE, IEC 62109, AS/NZS 4777.2VDE-AR-N 4105, EN 50549-1, CE, IEC 62109, AS/NZS 4777.2VDE-AR-N 4105, EN 50549-1, CE, IEC 62109, AS/NZS 4777.2VDE-AR-N 4105, EN 50549-1, CE, IEC 62109, AS/NZS 4777.2VDE-AR-N 4105, EN 50549-1, CE, IEC 62109, AS/NZS 4777.2VDE-AR-N 4105, EN 50549-1, CE, IEC 62109, AS/NZS 4777.2VDE-AR-N 4105, G98, G99, CEVDE-AR-N 4105, G98, G99, CEVDE-AR-N 4105, G98, G99, CE

File

Tipo: BROCHURE

Fronius Primo GEN24 3.0 Plus · Fronius Fronius Primo GEN24 3.0 Plus - Brochure

Apri file

Tipo: INSTALLATION_VIDEO

Fronius Primo GEN24 3.0 Plus · Fronius Fronius Primo GEN24 3.0 Plus - Installation Video

Apri file

Tipo: COMMISSIONING_GUIDE

Fronius Primo GEN24 3.0 Plus · Fronius Fronius Primo GEN24 3.0 Plus - Commissioning Guide

Apri file

Tipo: MARKETING_VIDEO

Fronius Primo GEN24 3.0 Plus · Fronius Fronius Primo GEN24 3.0 Plus - Marketing Video

Apri file

Tipo: PROMOTION_IMAGE

Fronius Primo GEN24 3.0 Plus · Fronius Fronius Primo GEN24 3.0 Plus - Promotion Image

Apri file

Tipo: CORPORATE_VIDEO

Fronius Primo GEN24 3.0 Plus · Fronius Fronius Primo GEN24 3.0 Plus - Corporate Video

Apri file

Tipo: CERTIFICATES

Fronius Primo GEN24 3.0 Plus · Fronius Fronius Primo GEN24 3.0 Plus - Certificates

Apri file

Tipo: DATASHEET_PDF

Fronius Primo GEN24 3.0 Plus · Fronius Fronius Primo GEN24 3.0 Plus - Datasheet

Apri file

Tipo: INSTALLATION_MANUAL

Fronius Primo GEN24 3.0 Plus · Fronius Fronius Primo GEN24 3.0 Plus - Installation Manual

Apri file

Tipo: WIRING_DIAGRAM

Fronius Primo GEN24 3.0 Plus · Fronius Fronius Primo GEN24 3.0 Plus - Wiring Diagram

Apri file

Tipo: PRODUCT_IMAGE

Fronius Primo GEN24 3.0 Plus · Fronius Fronius Primo GEN24 3.0 Plus - Product Image

Apri file

Tipo: DATASHEET_PDF

Fronius Primo-GEN24-3.0-Plus · Fronius Primo-GEN24-3.0-Plus Datasheet

Apri file

Tipo: PRODUCT_IMAGE

Fronius Primo-GEN24-3.0-Plus · Fronius Primo-GEN24-3.0-Plus Product Image

Apri file